Universal input 100 to 240 VAC
Single output option
Overload protection
100% Hi-Pot tested
100% cycling burnt-in.



Load regulation: 5%
Maximum power: 10W for convection cooled
Efficiency: 58~70% typical at full load and normal line input
Transient response: Main output 50-100% load and regulation within 5%
Short circuit protection: Pulsing mode, Auto recovery



Input voltage: 90 to 264 VAC
Input frequency: 47 to 63 Hz
Input current: 0.4A max at 100 VAC
Inrush current: 40 A max. for two cycles or less
Protection: 2 A fuse on board
Configuration: IEC 60320 C14



Topology: FLYBACK
Dielectric strength test: 3K VAC primary to secondary
Insulation resistance: 50M Ohm @ 500 VDC primary to secondary
Leakage current: less than 3.5 mA @ 240 VAC 50 Hz
MTBF: 50,000 hrs min. at full load and 25°C



Conducted / radiated emissions: 
Meet FCC Part 15 CLASS B, CISPR 22 CLASS B




Operating temperature, full load, no derating:0~40°C
Non-operating: -20~80°C
Relative humidity non-condensing: 0~95%
Altitude: Sea level up to 25,000 feet
Cooling: Convection cooled
Shock: Per MIL-STD-810C 516 Part V
Vibration: 10 to 500 Hz, 15 mins / cycle / axis