Input 100-120V or 220-240 VAC
Single output option
Overload protection
100% Hi-Pot tested
100% cycling burnt-in.


Load regulation: 5%
Maximum power: 15W for convection cooled
Hold up time: 10ms at full load, 120 VAC
Efficiency: 65% typical at full load
Transient response: Main output 50-100% load and output voltage meet spec.
Overvoltage protection: Main output
Short circuit protection: Main output
Overcurrent protection: Main output



Input voltage: 90-132 or 220-264 VAC
Input frequency: 47 to 63 Hz
Input current: 0.4 max at 90 VAC
Inrush current: 50 A max. for two cycles or less
Protection: 2 A fuse on board
Configuration: US 2 pin or Euro-plug


Topology: RCC
Dielectric strength test: 3K VAC primary to secondary, 4.24K VDC primary to secondary
Insulation resistance: 50M Ohm @ 500 VDC primary to secondary
Leakage current: Less than 0.25 mA @ 240 VAC 50 Hz
MTBF: 50,000 hrs min. at full load and 25°C


Conducted / radiated emissions: 
Meet FCC Part 15 CLASS B, CISPR 22 CLASS B



Operating temperature, full load, no derating : 0~40°C
Non-operating: -20~85°C
Relative humidity non-condensing: 0~95%
Altitude: Sea level up to 25,000 feet
Cooling: Convection cooled
Shock: Per MIL-STD-810C 516 Part V
Vibration: 10 to 500 Hz, 15 mins / cycle / axis