Universal input 100 to 240 VAC
Single output option
Over power protection
100% Hi-Pot tested
100% cycling burn-in.


Load regulation: กำ5%
Maximum Power: 36W for convection cooled
Hold up time: 16ms@FULL load,115 VAC
Efficiency: 80% typical at full load
Transient Response: 50-100%load 10% max. and output regulation meet spec.
Short circuit protection: Yes


Input voltage: 90 To 264 VAC
Input frequency: 47 to 63 Hz
Input current: 1.2 Amax at 100 VAC
Protection: 2 A fuse on board


Topology: Flyback
Dielectric Strength Test: 3K VAC primary to secondary
Leakage current: Less than 3.5 mA @ 240 VAC50 Hz
MTBF: 50000 hrs mim. at full load and 25°C


Conducted / Radiated emissions: 
Meet FCC Part 15 CLASS B, CISPR 22 CLASS B



Operating temperature, full load, no derating:0~40°C
Non-operating: -20~70°C
Relative humidity non-condensing: 0~95%
Altitude: Sea level up to 25,000 feet
Cooling: Convection cooled
Shock: Per MIL-STD-810C 516 Part V
Vibration: 10 to 500 Hz,15 mins/cycle/axis