Universal input 100 to 240 VAC
Single output
Overload protection
100% Hi-Pot tested
100% cycling burnt-in.


Line regulation: 0.20%
Load regulation: 5%
Maximum power: 60W for convection cooled
Hold up time: 20ms at full load, 120 VAC
Efficiency: 65% typical at full load, varies with distribution of loads among outputs
Transient response: main output 50-100% load 10% max. dev. 10 ms recovery
Overvoltage protection: All output
Short circuit protection: All output
Overcurrent protection: All output


Input voltage: 90 to 264 VAC
Input frequency: 47 to 63 Hz
Input current: 1.4A max at 90 VAC
Inrush current: 100 A max. for two cycles or less
Protection: 2 A fuse on board
Configuration: IEC 60320 C8, C6


Topology: FLYBACK
Dielectric strength test: 3K VAC primary to secondary
Insulation resistance: 50M Ohm @ 500 VDC primary to secondary
Leakage current: less than 0.25 mA @ 240 VAC 50 Hz
MTBF: 50,000 hrs min. at full load and 25¢XC


Conducted / radiated emissions: 
Meet FCC Part 15 CLASS B, CISPR 22 CLASS B



Operating temperature, full load, no derating:0~40¢XC
Non-operating: -20~85¢XC
Relative humidity non-condensing: 0~95%
Altitude: Sea level up to 25,000 feet
Cooling: Convection cooled
Shock: Per MIL-STD-810C 516 Part V
Vibration: 10 to 500 Hz, 15 mins / cycle / axis